Mitsuei industrial Group

Mitsuei ducted fan coil

  • Low noise, even at high speed
  • Available in 3 sizes ranging from 950 to 2250 CFM
  • Four-layer washable mesh filter made of perforated aluminum
  • Easy access to air vent valve and coil drain cap
  • Made in Iran

Mitsuei Fan coil components

Details of Mitsuei fan coil components are provided below to guide your informed selection of a quality product:

Fan and housing

فن و هوزینگ فن کویل
  • Fan and housing construction considering multiple factors including airflow, pressure, noise, weight, material, etc.
  • Primary focus on noise reduction with attention to the rotating assembly (motor and fan)
  • Optimal air discharge angle using best manufacturing techniques
  • Dynamic balancing of fans to prevent vibration and disturbing noise
  • Use of galvanized steel sheet for fan construction (lightweight and high strength)
  • Dynamic balancing of fans to prevent vibration and disturbing noise
  • Use of permissible 1100 RPM speed in this fan coil model (maximum permissible fan speed 1300 RPM)

3-row coil

کویل سه ردیفه
  • Formed aluminum fins
  • Fin collar connection to tubes via mechanical expansion using fully automated machines for maximum heat transfer
  • Seamless 3/8-inch copper tubes complying with ASTM standard, thickness 0.35 to 0.41 mm
  • Welding of copper tubes to headers and brass collectors
  • Coil testing at 400 psig pressure in a water tank

Electromotor

03
  • Design and production of fan coil electromotors specifically to meet the unique requirements of refrigeration systems (fan coils)
  • Proper operation of these electromotors at ambient temperatures up to 50°C, tolerance for voltage fluctuations up to 10%, and frequency variations up to 5%
  • Capability to provide a wide range of nominal speeds (7 different speeds) in these electromotors (3 selectable speeds)
  • Guaranteed quality, high efficiency, and very low acoustic noise in these electromotors due to unique design, advanced manufacturing machinery, and standardized testing
  • Manufactured by Electrogen Company under license from SISME, Italy

Sound insulation

عایق صوتی فن کویل
  • Use of 9mm thick self-adhesive elastomeric insulation
  • Elastomeric insulation as a suitable alternative to traditional insulation materials
  • Featuring the lowest heat transfer coefficient and playing a significant role in enhancing product quality and efficiency by preventing vibration and sound transmission
  • High resistance to accumulation of pollutants and moisture, inhibiting growth of bacteria, pathogens, and fungi

Connections

اتصال بدنه فن کویل
  • Connection of all components and plates with the best available imported screws in Iran
  • Mitsuei's proprietary mold specifically designed for mutually perpendicular plates to achieve maximum strength
  • No use of rivets due to generation of disturbing noise and excessive vibration during long-term operation

Brass collector

04
  • Production of two sensitive components via brass casting and forging to ensure balanced water distribution under pressure within the coil tubes and its proper outflow.
  • Inclusion of an air vent valve at the highest point of the water return line to purge air from the coil.
  • Water drainage through a transparent plastic tube to the drain tray.

Electrical box

06
  • Location of the electrical terminal and wire connections.
  • This metal box is positioned on the opposite side of the unit's piping to adhere to safety precautions.

3-layered filter

02
  • The fan coil filter includes 2 layers of aluminum mesh formed in a sinusoidal wave pattern.
  • A fine-mesh polypropylene fabric is placed between the 2 layers of perforated aluminum to maximize the absorption of fine particles.
  • These layers are housed in a frame made of 1.5 mm thick galvanized sheet, 210 mm wide, and in various lengths.
  • Easily removable for servicing and cleaning.

Earth wire

06

Provision of an earth (ground) wire in accordance with existing standards.

Drain tray

Drain-2.jpg
  • Placement of a drain tray beneath the unit, specifically under the coil, to collect and discharge water droplets from condensation.
  • Inclusion of a proper slope and a 1/2-inch pipe for draining the condensate to the outside.
  • The drain tray is made of 1 mm thick galvanized sheet.
  • External covering with 9 mm thick thermal insulation foam.
  • An inner coating on the tray to prevent corrosion.

Pipe caps

01

Equipping the coils with temporary red and blue caps to prevent dust and debris from entering before connection to the supply and return water pipes.

Pipe connection side

09

Piping can be configured from either the right or left side of the fan coils, based on prior order according to installation conditions.

Fresh air

10
  • Possibility of connecting a fresh air duct to one side of the unit.
  • A 10 cm diameter circle is provided on the unit body (as shown in the adjacent photo). If a fresh air system is designed, it allows for mixing up to 40% of the intake air with fresh air (removable by the installer).

Body

connectors-2.jpg
  • All body components of the fan coil unit are made of 1 mm thick galvanized sheet.
  • All panels are laser-cut.

Packaging

08
  • Use of the highest quality materials and adherence to packaging standards to ensure the product's integrity during transport and handling to the final site of operation.
  • The unit is shrink-wrapped after quality control approval to prevent dust and small stones from entering the device (before final commissioning in building workshops).

Unit servicing

07

Easy filter cleaning to achieve optimal device performance (timely cleaning is necessary as the filter becomes clogged).

The need to maintain a proper distance between the access panel and the unit.

Easy access to the fan blade, electromotor, and air vent valve when the aforementioned installation conditions are met.

Easy access to the electrical box to change the electromotor speed.

Installation

install-2.jpg
  • Easy installation with metric screws to the metal frame embedded in the false ceiling.
  • Ability to connect the unit's air output to a flexible duct using the flange and holes on the edge of the fan coil's outlet.

Quality control

05
  • Application of quality assurance and control principles and fundamentals towards producing an excellent and flawless product.
  • Conducting numerous tests, including vibration, noise, motor speed, torque, and output air volume and velocity, to enhance quality.
  • Quality control on incoming components, during the production process, and on the final product.

Model coding guide Mitsuei ducted fan coil

To understand the meaning of each section, click on the circle below that section.

Mitsuei fan coil

سایز یونیت

C : مدل سقفی توکار

D : مدل کانالی

پلنیوم

جهت اتصال چپ یا راست

Models Mitsuei ducted fan coil

MF304-DP

Airflow: 1100 ~ 950 CFM
تعداد موتور : 1 عدد
Power: 187 ~ 360 Watts
Length: 99 cm
Width: 67.7 cm
Height: 45 cm
وزن : 55 کیلوگرم

MF404-DP

Airflow: 1100 ~ 1500 CFM
تعداد موتور : 1 عدد
Power: 187 ~ 360 Watts
Length: 133 cm
Width: 67.7 cm
Height: 45 cm
وزن : 75 کیلوگرم

MF504-DP

Airflow: 1600 ~ 2250 CFM
تعداد موتور : 1 عدد
Power: 360 ~ 600 Watts
Length: 151 cm
Width: 67.7 cm
Height: 45 cm
وزن : 95 کیلوگرم

Download Catalogues

Mitsuei ducted fan coil catalogue
6 MB
Mitsuei general fan coil catalogue
6 MB

Ducted fan coil details

Airflow (CFM)

950 ~ 2250

Noise

Minimal noise even at high speed due to balanced fan blades.
All internal spaces are covered with 9 mm thick elastomeric insulation.

Material

The drain tray is made of 1.25 mm and 2 mm thick galvanized sheet.

Coil

4 rows of 3.8 inch copper tubes
12 aluminum fins per inch (FPI) with low static pressure drop.
Coil testing at a preset 400 psig in a water tank.
Maximum pressure tolerance of copper pipes: 1700 kPa, equivalent to 250 psig.

Electromotor

Single-phase 220V capacitor type.
2 z ball bearings
Made by Electrogen

Fan and housing

Balanced Centrifuge fan
Galvanized

Drain tray

Galvanized or stainless steel, as per order.
Insulated from the bottom with 6 mm elastomeric foam.

Sound insulation

9 mm thick elastomeric insulation.
A suitable alternative to traditional insulation materials.
Has the lowest heat transfer coefficient.
Prevents the transmission of vibration and sound.
Very high resistance to the accumulation of pollutants and moisture.
Resists the growth of bacteria, pathogens, and fungi.

Filter

Four-layer washable mesh filter made of perforated aluminum
16 mm tickness
Washable
Encased in foam frame to prevent noise

Connections

Connection of all components and plates with the best screws available in Iran.
Use of Mitsuei's proprietary chuck screws on perpendicular plates to achieve maximum strength.
No use of any rivets or spot welds, as they cause disturbing noise and excessive vibration during long-term operation.

Packaging

Strapped cardboard box.
Shrink-wrapped (prevents dust entry from installation to commissioning).
Coils equipped with red and blue caps (prevents dust entry from installation to commissioning).

Quality control

Application of quality assurance principles towards producing an excellent and flawless product.
Conducting numerous tests, including vibration, noise, motor speed, torque, and output air volume and velocity, to enhance quality.
Quality control on incoming components, during the production process, and on the final product.

Installation

Easy unit installation with metric screws to the metal frame in the false ceiling.

Other features

Equipped with an earth (ground) wire for grounding systems.

Customizations

Possibility of changing the connection pipe side (left or right).
Possibility of dual-coil configuration (cooling and heating).
Possibility of changing the drain tray material.

Fan coil FAQs

A fan coil is a type of dual-purpose heat exchanger. As its name suggests, it is composed of two main parts: a fan and a coil.

A tangible example for understanding how a fan coil works is a car's heater. In a car heater, hot engine water enters the heater radiator (the coil), and passing through it, the coil heats up. The heater fan then blows air over the coil, projecting warm air into the car's cabin.

For more information, read the "What is a Fan Coil?" article in the Mitsuei Magazine.

We use fan coils in places where we want to control the temperature of each part of a building separately.

Furthermore, by using fan coils, we prevent the transfer of contaminants between rooms. Therefore, we recommend using various types of fan coils in hotels, residential buildings, office buildings, and hospitals.

small_c_popup.png

با ما تماس بگیرید، یا برای ما بنویسید و یا به دفتر ما بیایید.

منتظر تماس شما هستیم.

021 562 77 114 – 16

021 562 77 510 – 13

تهران، آزادگان، احمدآباد مستوفی، خیابان انقلاب، کوچه پارسا
کد پستی : 33131-93731